Burn-free fireclay brick
PRODUCT SPECIFICATIONS
GB/T 34188
Items | PN-30 | |
ω(Al2O3) / % | μ0≥ | 30 |
σ | 2.5 | |
ω(Fe2O3) / % | μ0≤ | ---- |
σ | ≤0.4 | |
Apparent porosity / % | μ0≤ | 23(25) |
σ | 2.0 | |
Cold crushing strength / MPa | μ0≥ | 30(25) |
Xmin | 20(15) | |
σ | 10 | |
0.2MPa Refractoriness under load T0.6/℃ | μ0≥ | ≥1300 |
σ | 13 | |
Permanent linear change /% | U-L | 1300℃×2h -0.4~0.1 |
Note 1: The values in parentheses are indicators for grid bricks or special type bricks.
Note 2: Recommended use: PN-30 can be applied to semi silica bricks for coke ovens and alkali resistant bricks for general industrial furnaces.
Note 3: μ0 represents the mean value of qualified quality batches, σ represents the estimated value of batch standard deviation, U represents the upper specification limit, and L represents the lower specification limit.